Team:NGSS TR/lb.html
From 2014hs.igem.org
(Difference between revisions)
Line 171: | Line 171: | ||
</section> | </section> | ||
</div> | </div> | ||
+ | <blockquote> | ||
+ | <p> </p> | ||
+ | <blockquote> | ||
+ | <h1>PROTOCOLS</h1> | ||
+ | <blockquote> | ||
+ | <h2 class="gfdg">5.LB PREPARATION</h2> | ||
+ | <blockquote> | ||
+ | <p><strong><em><u>LB-BROTH</u></em></strong><br /> | ||
+ | <strong>Materials:</strong><br /> | ||
+ | <strong>- LB-Broth(chemical storage)</strong><br /> | ||
+ | <strong>- Sterile dH2O</strong><br /> | ||
+ | <strong>- Flask </strong><br /> | ||
+ | <strong>- Lab skale</strong><br /> | ||
+ | <strong>- Liquid autoclave</strong><br /> | ||
+ | <strong>- Alumininum folio</strong><br /> | ||
+ | <strong>- Antibiotic</strong></p> | ||
+ | <p><a name="_GoBack" id="_GoBack"></a><strong>Experiment:</strong><br /> | ||
+ | <strong>1. In a steril environment, the tare of the container should be measured and subtracted from the overall weight.</strong><br /> | ||
+ | <strong>2. 4 grams of LB Broth is put in the container.</strong><br /> | ||
+ | <strong>3. Add 200 ml distilled water to graduated cyclindar.</strong><br /> | ||
+ | <strong>4. These two are mixed in a beaker.</strong><br /> | ||
+ | <strong>5. When you are opening the beaker be sure that it doesn’t contact with air.</strong><br /> | ||
+ | <strong>6. Autoclave tape is sticked on to the aliminium.</strong><br /> | ||
+ | <strong>7. The beaker is placed in to the autoclave machine.</strong><br /> | ||
+ | <strong>8. Autoclave machine has to have distilled water or demineralized water. The water level in the autoclave machine has to be a little higher than the liquid level of the beaker.</strong><br /> | ||
+ | <strong>9. Then start the 90 min.</strong><br /> | ||
+ | <strong>10. Take out the beaker and add antibiotics if required.</strong></p> | ||
+ | <h2><strong>Attention!</strong><br /> | ||
+ | <strong>v Don’t be far away fire.</strong><br /> | ||
+ | <strong>v Don’ forget to write date </strong></h2> | ||
+ | <p> </p> | ||
+ | <p><strong><em><u>LB-Agar</u></em></strong><br /> | ||
+ | <strong>Materials:</strong><br /> | ||
+ | <strong>- LB-Agar(chemical storage)</strong><br /> | ||
+ | <strong>- Sterile dH2O</strong><br /> | ||
+ | <strong>- Flask </strong><br /> | ||
+ | <strong>- Liquid autoclave</strong><br /> | ||
+ | <strong>- Aluminium folio</strong><br /> | ||
+ | <strong>- Antibiotic</strong><br /> | ||
+ | <strong>- Empty plates</strong><br /> | ||
+ | <strong>- Parafilm</strong></p> | ||
+ | <p><strong>Experiment:</strong><br /> | ||
+ | <strong>1. In a steril environment, the tare of the container should be measured and subtracted from the overall weight.</strong><br /> | ||
+ | <strong>2. 7 grams of LB Agar is put in the container.(If there is no LB agar, add the 4 gram LB broth and 2,7 gram agar.)</strong><br /> | ||
+ | <strong>3. Add 200 ml distilled water to graduated cyclindar.</strong><br /> | ||
+ | <strong>4. These two are mixed in a beaker.</strong><br /> | ||
+ | <strong>5. When you are opening the beaker be sure that it doesn’t contact with air.</strong><br /> | ||
+ | <strong>6. Autoclave tape is sticked on to the aliminium.</strong><br /> | ||
+ | <strong>7. The beaker is placed in to the autoclave machine.</strong><br /> | ||
+ | <strong>8. Autoclave machine has to have distilled water or demineralized water. The water level in the autoclave machine has to be a little higher than the liquid level of the beaker.</strong><br /> | ||
+ | <strong>9. Then start the 90 min.</strong><br /> | ||
+ | <strong>10. Take out the beaker and add antibiotics if required.</strong><br /> | ||
+ | <strong>Attention!</strong><br /> | ||
+ | <strong>v Don’t be far away fire.</strong><br /> | ||
+ | <strong>v Don’ forget to write the date.</strong><br /> | ||
+ | <strong>v Don't forget add the amtibiotics</strong></p> | ||
+ | </blockquote> | ||
+ | </blockquote> | ||
+ | </p> | ||
+ | </blockquote> |
Latest revision as of 11:48, 20 June 2014